Principal Advantages :
Applications
This meter is more suitable with those fluids which present difficulties in handling. Fluids such as effluents, slurries, pulps, brines & other highly corrossive liquids, acids & bases, fermenterwash, molasses etc.
Following industries can find lot of application of this flow measurement technique.
Electromagnetic Flow-Meter (Full Bore) :
Specifications :
Sr. No. | Metering Tube | : |
Sroat 1000 |
1. | Meter Size | : |
DN 10 to DN 350 for higher sizes consult factory |
2. | Media Pressure | : |
Upto DN 80- PN 40 From DN 100 to DN 200 - PN 16 DN 250 to DN 350 - PN 10 |
3. | Media Temperature | : |
PFA Liner : 0 - 200°C max. PTFE Liner : 0 - 150°C max. Rubber Liner : 0 - 90°C max. |
4. | Ambient Temperature Range |
: |
0 - 50°c |
5. | Materials : Pipe | : |
SS 304 [non-magnetic ] |
Electrode | : |
SS 316 / SS316L/Hastelloy C / Ta /Ti. | |
Liner | : |
PTFE / Neoprene /Soft Rubber /Hard Rubber/PFA. | |
Flanges | : |
Carbon Steel / SS 316 / SS 316 L / SS 304. | |
Body Material | : |
Carbon Steel, P. U.painted./ SS 304/ SS 316 | |
6. | Flange Standard | : |
ANSI / DIN /BS / SMS / Triclamp |
7. | Power Supply to field coils | Pulsed DC | |
TRANSMITTER SROAT 1000 A | |||
1. | Mounting | : |
Remote Mounted [standard] Integral mounted [on request] |
2. | Min. Media Conductivity | : |
5 µs /cm [for lower conductivities consult factory] |
3. | Signal Output Additional option |
: |
4-20 mA dc isolated in max. 600 ohms Pulsed Output With adjustable count rate from 1 count / Hr to 10 Counts / Hr. [Open collector with 100 mA/24 V dc capacity] |
4. | Coil Excitation Frequency | : |
Selectable by DIP switch. a) 25Hz |
5. | Local Display | : |
a) 3 ½ digit LCD calibrated in % or in engineering units for flow rate indication b) 8 digit LCD non resettable type for totalised quantity. |
6. | Flow Velocity Range | : |
0.1 m/s to 10 m/s |
7. | Accuracy | : |
±0.5% of reading [at ref. conditions] between 100% to 10% of calibrated range ±0.75% of reading for flow rate between 10% to 5% [refer accuracy graph ] |
8. | Ref. Conditions | : |
Power supply nominal. Temperature 27°c ± 2°c |
9. | Repeatability | : |
±0.2% of reading |
10. | Ambient Temperature | : |
0 50°c |
11. | Temperature Drift | : |
±0.015% per °c max. |
12. | Humidity | : |
90 % R. H. max. non condensing |
13. | Material of Housing | : |
Al. Die cast. |
14. | Power Supply | : |
230 V ac/ 110 V ac, 50 Hz/24 V dc. |
15. | Damping | : |
Adjustable from 5 to 30 Secs. |
16. | Cable Entries | : |
4 no. For Remote Amplifier |
17. | Ingress Protection | : |
IP-67 |